SERVICE AND PARTS MANUAL
FRYMASTER BIELA14 SERIES GEN II
LOV™
ELECTRIC FRYER
Frymaster L.L.C., 8700 Line Avenue, Shreveport, LA 71106
PHONE 318-865-1711 FAX 318-219-7135
PRINTED IN THE UNITED STATES SERVICE HOTLINE
1-800-24-FRYER MAY 2011
www.frymaster.com
email: [email protected] *8196446*
FOR YOUR SAFETY
Do Not Store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
This equipment chapter is to be
installed in the Fryer Section of the
Equipment Manual.
MANUFACTURED
BY
8700 Line Avenue
SHREVEPORT, LOUISIANA 71106
PHONE: 1-318-865-1711
TOLL FREE: 1-800-551-8633
1-800-24 FRYER
FAX: 1-318-688-2200
Zobrazit stránku 0
1 2 3 4 5 6 ... 95 96

Shrnutí obsahu

Strany 1 - *8196446*

SERVICE AND PARTS MANUAL FRYMASTER BIELA14 SERIES GEN II LOV™ ELECTRIC FRYER Frymaster L.L.C., 8700 Line Avenue, Shrev

Strany 2

1-3 1.4 Replacing a High-Limit Thermostat 1. Remove the filter pan and lid from the unit. Drain the frypots into an McDonald’s Shortening Disposa

Strany 3

1-4 4. Locate the red (or yellow) and white wires of the temperature probe to be replaced. Note where the leads are connected prior to removing the

Strany 4

1-5 1.6 Replacing a Heating Element 1. Perform steps 1-5 of section 1.5, Replacing a Temperature Probe. 2. Disconnect the wire harness contain

Strany 5

1-6 1425361425367895R4R6R1R2R3RIndex Marker marks Position 15L 4L6L 1L2L3L Full vat element wire routing Pull the element wires through the bushin

Strany 6 - TABLE OF CONTENTS

1-7 8. Reconnect the element connector ensuring that the latches lock. 9. Insert the temperature probe leads into the 12-pin wiring harness connec

Strany 7 - TABLE OF CONTENTS cont

1-8 4. The contactors and relays are held on by threaded pin studs so that only removal of the nut is required to replace the component. 5. After p

Strany 8

1-9 3. Slide the metal bezel up to release the bottom tabs, then slide the bezel down to disengage the upper tabs. 4. Remove the two screws from t

Strany 9 - Remove these two screws

1-10 23. Position the element tube assembly in the frypot and reinstall the machine screws and nuts removed in step 19. 24. Reconnect the oil return

Strany 10

1-11 • Solidified shortening in the pan or filter lines, or • Attempting to filter unheated oil or shortening (cold oil is more viscous, overloadin

Strany 11 - Metal Wire Tie

1-12 Disconnect flexlines indicated by the arrows. 4. Loosen the nut and bolt which secure the bridge to the oil-return manifold. 5. Remove the

Strany 12

NOTICE IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS MANITOWOC FOOD SERVICE EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PAR

Strany 13

1-13 1.10 ATO (Automatic Top-off) Service Procedures The automatic top-off system is activated when the oil level falls below a sensor in the rear

Strany 14

1-14 Problem Probable Causes Corrective Action Frypots won’t top off. A. Empty JIB. B. Probe temperature lower than setpoint. C. Oil is too cold

Strany 15

1-15 1.10.2 ATO (Automatic Top-Off) Board Pin Positions and Harnesses Connector From/To Harness # Pin # Function Voltage Wire Color J8 RTI Add Sole

Strany 16

1-16 1.10.3 Replacing the ATO board, LON Gateway, ATO pump relay or Transformers Disconnect the fryer from the electrical power supply. Locate the

Strany 17

1-17 Buttons and LED’s Manual – This button is used to toggle between auto and manual filtration mode. A corresponding LED is lit when in Manual mo

Strany 18 - Down for forward

1-18 1.11.2 MIB (Manual Interface Board) Troubleshooting Problem Probable Causes Corrective Action Auto filtration won’t start. A. Filter pan o

Strany 19

1-19 Problem Probable Causes Corrective Action MIB board alternating “E” and “vat number and side”. Network error on the CAN bus communication. A. En

Strany 20

1-20 1.11.3 MIB (Manual Interface Board) Pin Positions and Harnesses Connector From/To Harness # Pin # Function Voltage Wire Color J1 M3000 J7

Strany 21

1-21 1.11.4 MIB (Manual Interface Board) Display Diagnostics DISPLAY LED EXPLANATION Drain Vat # (The vat number is followed by an “L” to ind

Strany 22

1-22 1.11.5 MIB (Manual Interface Board) Display Characters A – Auto Mode – Auto Filtration enabled. E – Drain or return valve is not in desired sta

Strany 23

DANGER Improper installation, adjustment, maintenance or service, and unauthorized alterations or modifications can cause property damage, injury, or

Strany 24

1-23 1.12 RTI Service Issues 1.12.1 RTI MIB Tests The LOV™ fryer will ONLY operate with RTI systems that have the new RTI updated three-pole floa

Strany 25

1-24 1.12.2 RTI LOV™ Wiring 1.12.3 Frymaster LOV™ Fryer and RTI Bulk Oil System Plumbing Schematic

Strany 26

1-25 1.12.4 RTI LOV™ TEST QUICK REFERENCE DISPOSE TO WASTE, REFILL VAT FROM BULK: 1. Hold down “Filter” button until computer beeps twice. 2. Scr

Strany 27

1-26 8. “Filling” is displayed during fill. 9. Release button to stop filling. 10. “Continue Filling? Yes/No” is displayed. 11. Press “8” to exit.

Strany 28

1-27 1.13 AIF (Automatic Intermittent) Filtration Service Procedures The AIF (Automatic Intermittent Filtration) board controls the actuators that

Strany 29 - Figure 12

1-28 1.13.2 AIF (Auto Intermittent Filtration) Actuator Board Pin Positions and Harnesses Connector From/To Harness PN Pin # Function VoltageWi

Strany 30

1-29 1.13.3 Replacing an AIF (Automatic Intermittent Filtration) board Disconnect the fryer from the electrical power supply. Locate the AIF board

Strany 31 - 1.12.2 RTI LOV™ Wiring

1-30 1.13.5 Replacing a Rotary Actuator Disconnect the fryer from the electrical power supply. Locate the actuator to be replaced and mark and unp

Strany 32 - FILL VAT FROM BULK:

1-31 Problem Probable Causes Corrective Action M3000 display shows ENERGY MISCONFIGURED Wrong energy type selected in setup. Press 1234 to enter set

Strany 33 - FILL JUG FROM BULK:*

1-32 Problem Probable Causes Corrective Action M3000 display shows TEMP PROBE FAILURE. A. Problem with the temperature measuring circuitry includin

Strany 34 - Figure 13

ii LOV™ ELECTRIC WARRANTY STATEMENT Frymaster, L.L.C. makes the following limited warranties to the original purchaser only for this equipment and re

Strany 35

1-33 Problem Probable Causes Corrective Action M3000 display shows IS VAT FULL? YES NO. A filter error has occurred due to dirty or clogged filter p

Strany 36

1-34 1.14.3 Service Required Errors A SERVICE REQUIRED error alternating with YES displays on the computer. After YES is pressed the alarm is sile

Strany 37

1-35 1.14.4 Error Log Codes Refer to page 1-39, level 2 program for access to the E-log. The ten most recent errors are listed from A-J, with A be

Strany 38

1-36 1.14.5 Tech Mode Tech mode allows technicians to reset all passwords set in levels one and two and change when the fryer calls for a filter pa

Strany 39

1-37 1.14.6 M3000 Filter Error Flowchart Change filter pad and ensure filter pan is pulled out for a minimum of 30 seconds.Fryer returns to cook mo

Strany 40

1-38 1.14.7 M3000 Menu Summary Tree Reflected below are the major programming sections in the M3000 and the order in which submenu headings will b

Strany 41

1-39 1.14.8 M3000 Board Pin Positions and Harnesses Connector From/To Harness PN Pin # Function Voltage Wire Color J1 SD Card J2 Interface Board

Strany 42 - Code ERROR MESSAGE

1-40 1.15 Loading and Updating Software Procedures Updating the software takes approximately 30 minutes. The software only needs to be loaded

Strany 43

1-41 1.16 BIELA14 Series LOV™ Data Network Flowchart

Strany 44 - DISPLAYED

1-42 1.17 Interface Board Diagnostic Chart The following diagram and charts provide ten quick system checks that can be performed using only a multi

Strany 45

iii • no fryer will be warranted under the ten-year program for which a proper start-up form has not been received. This warranty also does not cove

Strany 46

1-43 1.18 Probe Resistance Chart Probe Resistance Chart For use with fryers manufactured with Minco Thermistor probes only. F OHMS C F OHMS C F

Strany 47

1-44 1.19 Wiring Diagrams 1.19.1 Component Wiring (Domestic)

Strany 48

1-45 1.19.2 Component Wiring (CE)

Strany 49

1-46 1.19.3 Component Wiring (CSA)

Strany 50 - Probe Resistance Chart

1-47 1.19.4 Component Wiring (Australia)

Strany 51

1-48 1.19.5 Contactor Box – Delta Configuration

Strany 52

1-49 1.19.6 Contactor Box – WYE Configuration

Strany 53

1-50 1.19.7 Simplified BIELA14 LOV™ Gen II Series – Full Vat Delta Wiring

Strany 54

1-51 1.19.8 Simplified BIELA14 LOV™ Gen II Series – Dual Vat Delta Wiring

Strany 55

1-52 1.19.9 Simplified BIELA14 LOV™ Gen II Series – Full Vat Wiring EXPORT WYE

Strany 56

iv BIELA14 SERIES GEN II LOV™ ELECTRIC FRYERS TABLE OF CONTENTS CAUTIONARY STATEMENTS ...

Strany 57

1-53 1.19.10 Simplified BIELA14 LOV™ Gen II Series – Dual Vat Wiring EXPORT WYE

Strany 58

1-54 1.19.11 BIELA14 Gen II Series LOV™ Simplified Wiring

Strany 59

2-1 BIELA14 SERIES GEN II LOV™ ELECTRIC FRYERS CHAPTER 2: PARTS LIST 2.1 Accessories ITEM PART # COMPONENT 1 809-0171 Thumbscrew, ¼ -20 X

Strany 60

2-2 2.2 Doors, Sides, Tilt Housings, Cap-N-Splash, Top Caps and Casters ITEM PART # COMPONENT 1 231-0323 Side, Standard Cabinet Left SS (use 2

Strany 61

2-3 2.3 Drain System Components 2.3.1 Drain Tube Sections and Associated Parts ITEM PART# COMPONENT 1 823-6020 Drain Tube, Full-Vat Left

Strany 62 - CHAPTER 2: PARTS LIST

2-4 2.3.2 Drain Valves and Associated Parts 2.3.2.1 Linear Actuator Drain Valves ITEM PART # COMPONENT 1 809-0540 Nut, ½-13 2-Way Hex Loc

Strany 63 - * Not illustrated

2-5 2.4 Electronics and Wiring Components 2.4.1 Component Boxes

Strany 64

2-6 2.4.1 Component Boxes cont. ITEM PART # COMPONENT 1 106-5592 Box Assembly, Component 2 200-3300 Bracket, Component Box Strain Relief 3

Strany 65

2-7 2.4.2 Contactor Boxes 2.4.2.1 Left and Right Contactor Box Configurations CANADIAN 14kW RIGHT CONFIGURATIONSLEFT HAND BOX COVERSTANDARD MECHA

Strany 66 - 2.4.1 Component Boxes

2-8 2.4.2.1 Left and Right Contactor Box Configurations cont. NOTES: Left and right contactor box assemblies are mirror images of one another. Wit

Strany 67

v BIELA14 SERIES GEN II LOV™ ELECTRIC FRYERS TABLE OF CONTENTS cont. 1.19.3 Component Wiring CSA ...

Strany 68 - 2.4.2 Contactor Boxes

2-9 2.4.3 Heating Element Assemblies and Associated Parts 2.4.3.1 Element Assemblies and Hardware NOTE: These elements apply only to BIELA14

Strany 69

2-10 2.4.3.1 Element Assemblies and Hardware cont. ITEM PART # COMPONENT 1 Element 826-2198 200V 7.0 kW (220V 8.5kW used in some export 3-p

Strany 70

2-11 2.4.3.2 Element Tube Assemblies FULL-VAT ELEMENT ASSEMBLYDUAL-VAT ELEMENT ASSEMBLY1245678910113

Strany 71

2-12 2.4.3.2 Element Tube Assemblies contd. ITEM PART # COMPONENT 1 108-0297SP Tube Assembly RE Element, Full-Vat 2 108-0298SP Tube Assembly

Strany 72

2-13 2.4.5 Wiring 2.4.5.1 Contactor Box Wiring Assemblies – 12-Pin Dual-Vat C-1 ITEM PART # COMPONENT 106-5980SP Contactor Box Harness A

Strany 73

2-14 2.4.5.3 Contactor Box Wiring Assembly – 6-Pin (Left Element) ITEM PART # COMPONENT 1 106-8744 14/17 kW Mechanical Contactor 2.4.5.4

Strany 74

2-15 2.4.5.5 Main Wiring Harnesses

Strany 75

2-16 2.4.5.6 Component Box and Filter Pump Wiring Harnesses ITEM PART # COMPONENT 1 106-5750SP Full Vat Control Harness J4 to J2 (Standard) 2

Strany 76

2-17 2.4.5.8 M3000, MIB, AIF and ATO Wiring Harnesses ITEM PART # COMPONENT * 807-4546 Computer Communication (used from Computer to Computer) *

Strany 77 - Board Wiring Harness

2-18 2.5 Filtration System Components 2.5.1 Filtration Components

Strany 78 - ™ RTI-MIB connector

1-1 BIELA14 SERIES GEN II LOV™ ELECTRIC FRYERS CHAPTER 1: SERVICE PROCEDURES 1.1 General Before performing any maintenance on your Frymaster fry

Strany 79

2-19 2.5.1 Filtration Components cont. ITEM PART # COMPONENT 1 823-7181 Lid, Multi-Vat Fryers, Standard Size Filter Pan 823-6684 Lid, Multi-V

Strany 80

2-20 2.5.2 Auto Intermittent Filtration Components 2.5.2.1 LOV™ Indicator Lights Assembly ITEM PART # COMPONENT 1 106-8106SP Light, Blue 24V

Strany 81 - √ Recommended parts

2-21 2.5.2.3 AIF Board Assembly 123456 ITEM PART # COMPONENT 108-1305 Assembly, AIF 1 824-1988 Cover, AIF Board 2 816-0814 Gasket, AIF Boar

Strany 82

2-22 2.6 Frypot Assemblies and Associated Parts 2.6.1 Frypots with Linear Actuators ITEM PART # COMPONENT 1 823-7436 Frypot, Full-Vat

Strany 83

2-23 2.6.2 Frypots with Rotary Actuators ITEM PART # COMPONENT 1 823-7672 Frypot, Full-Vat LOV™ 2 823-7673 Frypot, Dual-Vat LOV™ (use 823-7

Strany 84

2-24 2.7 Oil Return Manifolds ITEM PART # COMPONENT 1 810-3015 Manifold, Two-Station Fryer 2 810-3016 Manifold, Three-Station Fryer 3 810

Strany 85

2-25 2.8.1 Return Valves and Associated Parts (Linear Actuators) cont. ITEM PART # COMPONENT 1 232-5702 Handle, Return Valve with Locator FV or

Strany 86

2-26 2.9.2 JIB Cap and Pick Up Assembly cont. ITEM PART # COMPONENT 3 823-7738 Inlet, Oil Reservoir Tube 4 816-0870 Clamp 2.9.3 Automatic

Strany 87

2-27 2.9.4 ATO Pump Assembly ITEM PART # COMPONENT √ 1 108-0639 Pump, Shurflo 24VAC 2 810-3265 Flexline, ½” OD x 24-inch (

Strany 88

2-28 2.9.5 ATO Pump Assembly Service Kit (Larger Top Off Lines) INSTALL O-RINGS HERE546321137891011712 ITEM PART # COMPONENT

Strany 89

1-2 3. Remove the two screws from the upper corners of the computer and allow the computer to swing down. 4. Unplug the wiring harnesses and disconn

Strany 90 - 2.10 RTI

2-29 2.10 RTI 2.10.1 RTI Manifold and Accessories TO OIL RETURN MANIFOLDTO TOP OFF PUMP INTAKE AND TO FILL RTI JIB2725232426TO RTI BYPASS CHECK VALV

Strany 91

2-30 2.10.1 RTI Manifold and Accessories cont. ITEM PART # COMPONENT √ 1 106-6830 Solenoid Assembly 2 108-0446 Valve, RTI Waste Assembly (see pag

Strany 92

2-31 2.10.2 RTI Dispose Waste Valve ITEM PART # COMPONENT 108-0446 Valve, RTI Dispose Waste 1 108-0445 Bracket, RTI Waste Valve 2 220-561

Strany 93 - Power Cords

2-32 2.11 Wiring Connectors, Pin Terminals and Power Cords ITEM PART # COMPONENT Power Cords * 807-0154 100/120V–15A 3-wire, w/grounded plug

Strany 94

2-33 2.12 Fasteners ITEM PART # COMPONENT * 809-0429 Bolt, ¼-inch – 20 x 2.00-inch Hex Head ZP Tap * 809-0131 Bolt, ¼-inch -20 x ¾-inch Hex * 80

Strany 95

THIS PAGE INTENTIONALLY LEFT BLANK

Strany 96 - MAY 2011

Frymaster, L.L.C., 8700 Line Avenue, Shreveport, Louisiana 71106 TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 (Tech Support) 1-318-219-7135 PRIN